Input DC (PV side)
Recommended max. PV array size 6 kW 7.2 kW 10 kW 12 kW 16 kW
Max. usable PV input power 4.8 kW 5.76 kW 8 kW 9.6 kW 12.8 kW
Max. input voltage 500 V
Rated voltage 330 V
Start-up voltage 90 V
MPPT voltage range 90 – 435 V
Max. input current 16 A / 16 A 32 A / 32 A
Max. short circuit current 20 A / 20 A 40 A / 40 A
MPPT number / Max. input strings number 2 / 2 2 / 4
Battery
Battery type Li-ion / Lead-acid
Battery voltage range 40 – 60 V
Max. charge / discharge power 3 kW 3.6 kW 5 kW 6 kW 8 kW
Max. charge / discharge current 70 A 80 A 112 A 135 A 190 A
Communication CAN / RS485
Output AC (Grid side)
Rated output power 3 kW 3.6 kW 5 kW 6 kW 8 kW
Max. apparent output power 3 kVA 3.6 kVA 5 kVA 6 kVA 8 kVA
Operation phase L/N/PE
Rated grid voltage 220 V / 230 V
Rated grid frequency 50 Hz / 60 Hz
Rated grid output current 13.7 A / 13.1 A 16.4 A / 15.7 A 22.8 A / 21.8 A 27.3 A / 26.1 A 36.4 A / 34.8 A
Max. output current 13.7 A / 13.1 A 16.4 A / 15.7 A 22.8 A / 21.8 A 27.3 A / 26.1 A 36.4 A / 34.8 A
Power factor > 0.99 (0.8 leading – 0.8 lagging)
THDi < 2%
Input AC (Grid side)
Input voltage range 187 – 253 V
Max. input current 21 A 25 A 32 A 40 A 50 A
Frequency range 45 – 55 Hz / 55 – 65 Hz
Output AC (Back-up)
Rated output power 3 kW 3.6 kW 5 kW 6 kW 8 kW
Max. apparent output power 2 times of rated power, 10 s
Back-up switch time < 4 ms
Rated output voltage L/N/PE, 220 V / 230 V
Rated frequency 50 Hz / 60 Hz
Rated output current 13.7 A / 13.1 A 16.4 A / 15.7 A 22.8 A / 21.8 A 27.3 A / 26.1 A 36.4 A / 34.8 A
Max. AC passthrough current 35 A 35 A 40 A 40 A 50 A
THDv (@linear load) < 2%
Efficiency
Max. efficiency 96.2%
EU efficiency 96.1%
BAT charged by PV / AC max. efficiency 95.3% / 93.9%
BAT discharged to AC max. efficiency 93.8%
Protection
Ground fault monitoring Yes
DC reverse-polarity protection Yes
Integrated AFCI 2.0 Optional
Protection class / Over voltage category I / II (PV and BAT), III (MAINS and BACKUP and GEN)
General Data
Dimensions (W × H × D) 335 × 560 × 253 mm
Weight 23 kg 23.5 kg
Topology High frequency isolation (for battery)
Operating ambient temperature range -40 ~ + 60°C
Ingress protection IP66
Cooling concept Natural cooling Intelligent fan-cooling
Max. operation altitude 3000 m
Grid connection standard NRS 097-2-1, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA, NBR 16149, NBR 16150
Safety / EMC standard IEC/EN 62109-1/-2, EN 61000-6-2/-3
Features
DC connection MC4 plug (PV port) / Terminal Block (BAT port)
AC connection Terminal Block
Display 7.0″ LCD display & Bluetooth + APP
Communication RS485, CAN, Optional: Wi-Fi, GPRS, LAN

GSL Lithium Battery 14KW
Call for Price

Solis - S6-EH3P12K02-NV-YD-L
Call for Price
S6-EH1P(3-8)K-L-PLUS series energy storage inverter is suitable for residential PV energy storage system, support up to 32A MPPT current input, suitable for various high power PV panels; 6-stage timed charge and discharge function, integrated battery treatment and protection functions, more friendly to batteries. And can support multiple inverters in parallel to form a single-phase or three-phase system with a maximum power of 48kW. With UPS switching and provides an independent generator interface to make energy applications more reliable. The product provides solutions for demanding power scenarios with residential energy storage systems.
Call for Price
5 in stock
Product details
Color |
White |
---|---|
Brand |
Solis |